Routine equipment maintenance includes:
Cleaning the water inlet filter monthly to prevent blockage by impurities.
Dusting the condenser fins quarterly to maintain heat dissipation efficiency.
Replacing the water tank seal ring annually to prevent leaks.

 

Common troubleshooting:
Reduced ice production: Check the water pump pressure (normal value 0.15-0.3 MPa).
Ice cubes sticking together: Adjust the water temperature to the 2-5℃ range and calibrate the temperature sensor.
Abnormal noise: Check the gear meshing condition of the gearbox and replenish the lubricant.